CU EPR/CTS/PVC Pŵer Math MV-105 Cebl 35kV 100% IL. 345 mils Wedi'i warchod

CU EPR/CTS/PVC Pŵer Math MV-105 Cebl 35kV 100% IL. 345 mils Wedi'i warchod
Details:
· Dargludydd Copr Strand (heb ei lenwi / llenwi)
· Tarian Strand Allwthiol
· Inswleiddio: EPR
· Tarian Inswleiddio Allwthiol
· Tarian Tâp Copr
· Siaced Gyffredinol PVC
· Graddfa Foltedd: 5KV-35KV
· Tymheredd: 105 gradd
· Amrediad Maint: 2AWG ~ 1000kcmil
·Safon: UL1072
·Craidd sengl
· Lliw: du
Send Inquiry
Download
Disgrifiad
Paramedrau Technegol
Ardystiad

single conductor mv-105 cable

SHOT CYNNYRCH GO IAWN

 

single core mv-105 cable
copper conductor mv-105 cable
single core copper mv-105 cable

type mv-105 copper cable

Lefel Inswleiddio 35kV 100% - Pŵer Dibynadwy ar gyfer Porthwyr Is-orsaf a Diwydiannol Trwm
hwn35kV 100% lefel inswleiddio cebl foltedd canoligwedi'i gynllunio ar gyfer trawsyrru pŵer foltedd uchel dibynadwy mewn porthwyr is-orsafoedd, systemau ategol gweithfeydd pŵer, ac offer diwydiannol trwm. Wedi'i adeiladu gyda dargludydd copr pur, inswleiddio EPR, tarian tâp copr, a siaced gyffredinol PVC, mae'n darparu perfformiad cadarn gydaTrwch inswleiddio 345 mils. UL1072 ardystiediga Math MV-105 wedi'i raddio ar gyfer gweithrediad 105 gradd parhaus, mae'r cebl hwn yn bodloni gofynion llym rhwydweithiau dosbarthu pŵer cyfleustodau a diwydiannol. Mae'r inswleiddiad EPR yn cynnig ymwrthedd gwell i wres, lleithder a straen trydanol, tra bod y darian tâp copr yn darparu amddiffyniad sylfaen effeithiol ac ymyrraeth electromagnetig ar gyfer offer amddiffyn a rheoli sensitif. Mae'rsiaced PVC garwyn sicrhau ymwrthedd ardderchog i olew, cemegau, sgraffinio, ac amlygiad amgylcheddol, gan ei gwneud yn addas i'w osod mewn gorsafoedd cynhyrchu pŵer, cyfleusterau mwyngloddio, a chyfadeiladau diwydiannol mawr sy'n gofyn am ddosbarthiad foltedd uchel dibynadwy.
MANYLEBAU CYNNYRCH

 

type mv-105 medium voltage cable copper

Disgrifiad o'r Cynnyrch

 

Mae'r Foltedd Canolig, Tarian Tâp EPR/Cu/PVC, Cebl Math MV-105 yn cynnwys dargludyddion sownd copr noeth Dosbarth B wedi'u hanelio'n llawn, wedi'u gorchuddio â rwber ethylene propylen (EPR), tarian tâp copr, a siaced PVC du. Defnyddir y ceblau hyn mewn cylchedau pŵer diwydiannol.

Ceisiadau

 
  • Mewn cwndid, dwythell, aer rhydd, a llwybrau rasio, mae gosodiadau sylfaenol yn cynnwys hambyrddau cebl, a lleoliadau awyr agored
  • Mewn claddedigaeth uniongyrchol os caiff ei osod mewn system gyda dargludydd daear sy'n agos iawn, ac sy'n cydymffurfio â NEC 250.4 (A)(5)
  • Mewn lleoliadau gwlyb neu sych
  • Wedi'i gymeradwyo ar gyfer Dosbarth I, Div. 2 lleoliadau peryglus diwydiannol fesul NEC
  • Wedi'i gynllunio i weithredu'n barhaus ar dymheredd dargludydd nad yw'n uwch

105 gradd ar gyfer gweithrediadau arferol

140 gradd ar gyfer gorlwytho brys

250 gradd ar gyfer cylched byr

Nodweddion

 
  • Wedi'i raddio ar 105 gradd gwlyb neu sych
  • Gwrthiant corona ardderchog
  • Cryfder dielectrig uchel
  • Amsugno lleithder isel
  • Colled dielectrig isel
  • Gwrthiant golau haul ardderchog
  • Ar gyfer DEFNYDD CT am 1/0 AWG a mwy, fesul UL 1072
  • Yn cwrdd â phrawf plygu oer ar -35 gradd
MANYLION

Cyfrif Arweinydd

1 arweinydd

Arweinydd

Llinyn cywasgedig Dosbarth B copr noeth wedi'i anelio'n llawn (wedi'i lenwi neu heb ei lenwi)

Meintiau Mesurydd

Ar gael mewn 2 AWG trwy 1000 kcmil

Tarian Strand Arweinydd

Polymer dargludo lled-thermoset allwthiol dros y dargludydd

Inswleiddiad

Rwber Ethylene Propylene (EPR)

Tarian Inswleiddio

Polymer sy'n dargludo lled-thermoset allwthiol dros yr inswleiddiad

Tarian

Tâp copr anelio 5 milltir wedi'i gymhwyso'n helically gyda thua 25% yn gorgyffwrdd

Siaced

Polyvinyl clorid (PVC)

Marcio Siaced

2 AWG - 1 AWG:00000 FT LS Cable XXAWG 1/C XXKV XXX% LEFEL INSUL XXXMILS EPR/PVC JKT MATH MV-105 HAUL RES (UL) A WNAED YN UDA MMDDYYYY (BOLT GOLAU)
1/0 AWG - 1000 kcmil:00000 FT LS Cable XXAWG (neu XXXKCMIL) 1/C XXKV XXX% LEFEL INSUL XXXMILS EPR/PVC JKT MATH MV-105 AT DDEFNYDD CT (UL) HAUL RES A WNAED YN UDA MMDDYYYY (GOLEUADAU BOLT)

Pecynnu

Riliau pren na ellir eu dychwelyd mewn amrywiaeth o hydoedd a dimensiynau

Cydymffurfiaeth Perfformiad

ASTM B3|ASTM B8
UL 1072, UL 1685 (prawf amlygiad fflam)
ANSI/NEMA WC 74/ICEA S-93-639
ANSI/ICEA S-97-682
AEIC CS8
NEC

Cydymffurfiadau Eraill

EPA 40 CFR, Rhan 261
OSHA

Cdr Copr heb ei Lenwi/Llenwi 35kV 100% IL. 345 mils Wedi'i Gysgodi

Arweinydd
Maint

AWG/Kcmil

Nom. Arweinydd
Diamedr
Inswleiddiad
Diamedr

mewn(mm)
Trwch Siaced
mewn(mm)
Yn fras
Diamedr
mewn(mm)
Tua. Pwysau Net Ampacity
lbs/kft(kg/km) Cwnded mewn Awyr Duct tanddaearol
1/0 0.362(9.2) 1.12(28.4) 0.075(1.9) 1.36(34.5) 1,075(1,600) 215 215
2/0 0.405(10.3) 1.16(29.5) 0.075(1.9) 1.40(35.6) 1,200(1,786) 245 245
3/0 0.456(11.6) 1.21(30.7) 0.075(1.9) 1.45(36.8) 1,345(2,001) 280 275
4/0 0.512(13.0) 1.27(32.3) 0.075(1.9) 1.51(38.4) 1,525(2,269) 320 315
250 0.558(14.2) 1.32(33.5) 0.075(1.9) 1.57(39.9) 1,695(2,522) 350 345
350 0.661(16.8) 1.43(36.3) 0.075(1.9) 1.67(42.4) 2,085(3,102) 430 415
500 0.789(20.0) 1.56(39.6) 0.105(2.7) 1.87(47.5) 2,760(4,107) 525 500
750 0.968(24.6) 1.75(44.5) 0.105(2.7) 2.06(52.3) 3,695(5,498) 635 610
1000 1.117(28.4) 1.91(48.5) 0.105(2.7) 2.22(56.4) 4,595(6,837) 725 690
 
TYSTYSGRIFAU

 

single conductor medium voltage cable copper

PACIO

 

shielded single conductor mv-105 cable
Rîl Pren Mawr
mv-105 type mv cable copper conductor
Rîl Pren Mawr
CAIS

 

shielded single core mv-105 cable
Planhigyn Diwydiannol
mv-105 copper power cable
Cyfleuster Mwyngloddio
single core shielded medium voltage cable copper
Gwaith Pŵer
ACHOS

 

type mv-105 power cable copper conductor

System storio ynni batri

copper mv-105 shielded power cable

Gorsaf Bwer Bechatw

single conductor shielded power cable copper

Mwynglawdd Bingham Canyon

PAM DEWIS NI

 

30Blynyddoedd o brofiad
mewn-gwasanaeth un stop

Mae Dongguan Greater Wire & Cable Co., Ltd. yn wneuthurwr cebl gradd peirianneg proffesiynol yn Tsieina, sy'n cyflenwi datrysiadau cebl trydanol ardystiedig ar gyfer prosiectau adeiladu, diwydiannol, mwyngloddio, ynni a seilwaith ledled y byd.

Gyda ffatri 30,000 m², 30 llinell gynhyrchu, peirianwyr profiadol, a thîm rheoli ansawdd llym, rydym yn darparu cynhyrchion cebl dibynadwy, olrheiniadwy sy'n cydymffurfio ar gyfer cymwysiadau peirianneg rhyngwladol. Cefnogir ein cynnyrch gan ardystiadau gan gynnwys SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS, ac ISO.

Rydym wedi ymrwymo i ddiogelwch, ansawdd, tryloywder a phartneriaeth hirdymor. O archwilio deunydd crai i brofi cynnyrch gorffenedig, mae pob swp yn cael ei reoli'n ofalus i sicrhau perfformiad sefydlog a defnydd dibynadwy o'r prosiect.

Ansawdd Ardystiedig Cebl Mwy -. Cyflenwad Dibynadwy. Gwerth Peirianneg.

copper type mv-105 shielded cable
 
15K
Prosiectau Gorffenedig
150+
staff proffesiynol
15K
cleientiaid hapus
92+
gwobrau a thystysgrifau
OFFER PLANHIGION

 

single-core copper conductor type mv-105 cable
 
single-core copper mv-105 cable
 
single-core medium voltage cable copper conductor
 
mv-105 type mv cable copper conductor
 
copper conductor type mv cable 105c
 
single conductor copper type mv cable
 
TYSTYSGRIFAU BYD-EANG

 

mv-105 copper conductor power cable

LLUNIAU CWSMER
 

35kv mv-105 medium voltage cable copper conductor

TRAFNIDIAETH RHYNGWLADOL

 

01

Cludo Nwyddau Môr

Rydym yn cynnig datrysiadau cludo nwyddau môr dibynadwy ar gyfer archebion cyfaint mawr. Mae eich nwyddau'n cael eu pacio'n ddiogel a'u cludo mewn cynwysyddion, gan sicrhau cost-effeithiol danfon i borthladdoedd ledled y byd.

02

Cludo Nwyddau Awyr

Ar gyfer danfoniad cyflymach, mae ein gwasanaeth cludo nwyddau awyr yn sicrhau bod eich cynhyrchion yn cyrraedd cyrchfannau rhyngwladol yn gyflym, gyda thrin gofalus ac olrhain llawn ar hyd y ffordd.

03

International Express

Angen llwythi brys? Mae ein gwasanaeth cyflym rhyngwladol yn darparu archebion bach i ganolig yn effeithlon, gan ddarparu gwasanaeth o ddrws i ddrws gydag olrhain amser real er tawelwch meddwl.

35kv shielded copper mv-105 cable
PARTNER CYDWEITHREDOL

 

Rydym yn chwilio am bartner cydweithredol i ehangu ein busnes.

35kv single conductor medium voltage power cable copper
35kv copper tape shield mv-105 cable single conductor
35kv copper wire shield mv-105 cable single conductor
35kv xlpe insulated copper mv-105 cable single conductor
35kv epr insulated copper mv-105 cable single conductor
35kv type mv-105 power cable copper
35kv ul 1072 mv-105 cable copper conductor
ul 1072 single conductor type mv-105 cable
35kv type mv-105 power cable copper
35kv 105c mv cable copper single conductor
Sut i Gydweithredu â Ni?

Yn syml, rhannwch eich gofynion, derbyniwch ein datrysiad proffesiynol, cadarnhewch samplau, a mwynhewch gynhyrchu cyflym, dibynadwy a danfoniad byd-eang - gan weithio gyda ni mor hawdd â hynny.

Ein cyfeiriad

Adeilad 2, Na. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, China

Rhif Ffôn

+86 136 6257 9592

+86 135 1078 4550

E-bost

manager01@greaterwire.com

ul 1072 copper conductor mv-105 cable
FAQ

 

Beth yw'r gwahaniaeth rhwng inswleiddio 100% a 133% ar gyfer 35kV?
Mae 100% yn darparu amddiffyniad safonol ar gyfer gweithrediad arferol. 133% yn ychwanegu trwch ychwanegol ar gyfer cymwysiadau ag amodau gorfoltedd aml.
A ellir gosod y cebl hwn mewn hambyrddau cebl?
Ydy, yn dilyn bylchau priodol, clirio a gofynion cymorth ar gyfer ceblau foltedd uchel fesul cod.
Beth yw swyddogaeth y darian tâp copr?
Mae'n darparu llwybr dychwelyd cerrynt diffyg rhwystr isel, cyfyngiant maes trydan, cysgodi EMI, a sylfaen system ddiogel.
Pa gymwysiadau sy'n defnyddio cebl lefel inswleiddio 35kV 100%?
Porthwyr is-orsaf cyfleustodau, gwifrau generaduron offer pŵer, prif borthwyr diwydiannol mawr, a dosbarthiad pŵer mwyngloddio ag anghenion inswleiddio safonol.

 

Hot Tags: CU EPR/CTS/PVC Pŵer Math MV-105 Cebl 35kV 100% IL. 345 mils Shielded, Tsieina CU EPR/CTS/PVC Pŵer Math MV-105 Cebl 35kV 100% IL{{9} mils Shielded gweithgynhyrchwyr, cyflenwyr, ffatri

Send Inquiry